Fan-cooled Plate Cooling type
Directly-cooled plate surface absorbs heats from an object without heat losses
Features
Environment of use | Cooling method | Heat dissipation | Type of cooling |
Indoor | Thermoelectric | Air cooling | Plate |
Certificates/Approvals
EU RoHS2 | China RoHS | CE | UL | CSA | PSE |
Cooling cycle
Theremoelectric module absorbs heat from the plate and the cooled plate cools the object through heat transfer materials like thermal conductive grease in direct contact. The absorbed heat on plate side and the generated heat are cooled by fan to be dissipated through a heat conductive material like aluminum from the opposite side of a thermoelectric module. (*1)
(*1) The heat absorbed through the heat radiation fin is exhausted from the fan on heat dissipation side.
(*1) The heat absorbed through the heat radiation fin is exhausted from the fan on heat dissipation side.
Example of use
Model/Specifications
Model | OCE-F15P-D12 | OCE-F40P-D24 | OCE-F80P-D24 | |
Cooling method | Fan-cooled Plate cooling | |||
Cooling capacity *1 | 20W | 55W | 110W | |
Heating capacity *2 | 60W | 160W | 320W | |
Max. temperture difference in cooling *3 | 35K | 40K | 44K | |
Rated voltage | Fan | 12VDC ±5% | 24VDC ±5% | |
Peltier | ||||
Current consumption *4 | 3.5A or less | 4.5A or less | 9.0A or less | |
Starting current *5 | 4.5A | 5.7A | 11.3A | |
Working temperature | 0 to +60℃ | |||
Working humidity | Max. 80%RH, free from condensation | |||
Noise | 40dB(A) | 45dB(A) | ||
Max. allowable temeprature for Cooling palte | +80℃ | |||
Max. allowable temeprature for Dissipation fin base | +80℃ | |||
Vibration resistance | Vibration frequency 10-55Hz Total amplitude 0.7mm Cycle 5 min X, Y and Z axis 25min each |
|||
Conformity to standards | Environment | RoHS2 | ||
Dimensions (mm)※6 | W70×H90×D79 | W110×H135×D99 | W220×H150×D113 | |
Weight | 0.4kg | 1.0kg | 2.1kg |
*1 Nominal value at 30℃ ambient temp. by applying our capacity measurement method by product type
*2 Nominal value when both ambient and plate temperatures are 30℃
*3 Temperature difference between ambient air and cooling part when ambient temp. is 30℃ and heat load on plate surface is zero
*4 Rated value when the unit runs cooling operation at 30℃ ambient temp. (The value varies depending on temperature. See the table below. )
*5 Value at 30℃ ambient temp. (The value varies depending on temperature. See the table below. )
*6 Terminal board and projections are excluded.
*2 Nominal value when both ambient and plate temperatures are 30℃
*3 Temperature difference between ambient air and cooling part when ambient temp. is 30℃ and heat load on plate surface is zero
*4 Rated value when the unit runs cooling operation at 30℃ ambient temp. (The value varies depending on temperature. See the table below. )
*5 Value at 30℃ ambient temp. (The value varies depending on temperature. See the table below. )
*6 Terminal board and projections are excluded.
Correlation between temperature and current value
Ambient temperature | 0℃ | 15℃ | 30℃ | 45℃ | 60℃ | |
OCE-F15P-D12 (incl. 0.26A for fan) |
Rated current consumption (A) | 4.2 | 4.0 | 3.5 | 3.4 | 3.2 |
Starting current (A) | 5.0 | 4.8 | 4.5 | 4.3 | 4.0 | |
OCE-F40P-D24 (incl. 0.14A for fan) |
Rated current consumption (A) | 5.6 | 5.0 | 4.5 | 4.3 | 4.1 |
Starting current (A) | 6.4 | 6.0 | 5.7 | 5.3 | 4.9 | |
OCE-F80P-D24 (incl. 0.25A for fan) |
Rated current consumption (A) | 11.1 | 10.1 | 9.0 | 8.7 | 8.3 |
Starting current (A) | 12.7 | 12.0 | 11.3 | 10.5 | 9.8 |
Contents of page
OCE-F15P-D12
Cooling capacity
20W
A complete set of supply
BOXCOOL : 1 unit Instruction manual : 1 copy Heat insulator for mounting hole : 4 pcs.
OCE-F40P-D24
Cooling capacity
55W
A complete set of supply
BOXCOOL : 1 unit Instruction manual : 1 copy Heat insulator for mounting hole : 4 pcs.
OCE-F80P-D24
Cooling capacity
110W
A complete set of supply
BOXCOOL : 1 unit Instruction manual : 1 copy Heat insulator for mounting hole : 4 pcs.
System combination
By combination of BOXCOOL and components, various systems having different operation control from continuous operation to precise inversion control can be built.
①Continuous cooling
Combines BOXCOOL with a power supply for continuous running
Component name | Model | |||
OCE-F15P-D12 | OCE-F40P-D24 | OCE-F80P-D24 | ||
① | Switched-mode power supply | PBA75F-12-N | PBA150F-24-N | PBA300F-24 |
② | AC wiring *1 | WH-A-M4-2 | ||
③ | DC wiring | WH-P-M4-2、WH-F-M4-2 | WH-P-M5-2、WH-F-M5-2 |
*1 For 100VAC power supply
②Simple thermal control system
ON/OFF control is done by a temperature controller using a contact in the power supply.
Component name | Model | |||
OCE-F15P-D12 | OCE-F40P-D24 | OCE-F80P-D24 | ||
① | Temperature controller | OCE-TC91-8P3-1C | OCE-TC91-8Y1-1C | |
② | Switched-mode power supply | PBA75F-12-NR | PBA150F-24-NR | PBA300F-24 |
③ | Temperature sensor | OCE-TCPT12 | OCE-TCPT13 | OCE-TCPT14 |
④ | AC wiring *1 | WH-A-M4-2 | ||
⑤ | Wiring for temperature controller | WH-C2 | ||
⑥ | DC wiring | WH-P-M4-2、WH-F-M4-2 | WH-P-M5-2、WH-F-M5-2 |
*1 For 100VAC power supply
③Precise inversion control system
Highly precise temperature control is achieved by linear voltage controlled switching of cooling and heating using our Temperature Control system designed for BOXCOOL.
Component name | Model | |||
OCE-F15P-D12 | OCE-F40P-D24 | OCE-F80P-D24 | ||
① | Temperature Control System | OCE-TCR12075WL | OCE-TCR24150WL | OCE-TCR24300WL |
② | Temperature Sensor | OCE-TCPT12 | OCE-TCPT13 | OCE-TCPT14 |
③ | AC wiring ※1 | WH-A-M4-2 | ||
④ | DC wiring | WH-P-M4-2、WH-F-M4-2 |
*1 For 100VAC power supply
Related products
Cautions
・Avoid controlling supply voltage to the fan. Failure to this can be a cause of breakdown of the product.
・Do not use this product in a place where flammable or corrosive gasses, oil fume or any matters that can destroy insulation generate or permeate.
・The site of use should be free from vibration and impact.
・Electrical works required for installation of this product should be done only by professionals or qualified personnel.
・Indoor use only.
・Make sure that the packaging is not damaged on delivery. Any packaging damage can lead to breakdown of the product. Please contact us immediately if any damage is found.
・Do not use this product in a place where flammable or corrosive gasses, oil fume or any matters that can destroy insulation generate or permeate.
・The site of use should be free from vibration and impact.
・Electrical works required for installation of this product should be done only by professionals or qualified personnel.
・Indoor use only.
・Make sure that the packaging is not damaged on delivery. Any packaging damage can lead to breakdown of the product. Please contact us immediately if any damage is found.