Go to global navigation

Read the article

Go to local navigation

Go to footer



Environmental solution-OIL

Home > Environmental solution-OIL > Oil mist collector "MISTCATCH" lineup > Filter oil mist collector OMC-F series

Filter oil mist collector OMC-F series


99.8 % or higher collection rate! Low cost, high performance and energy saving

OMC-F

Features

Type Specifications
Filter Energy saving High collection rate Provided with Air volume indicator

Certificates/Approvals

EU RoHS2 China RoHS CE UL CSA PSE

Quick Selection

Model/Specifications

Model OMC-F105A OMC-F110A OMC-F120A
Max. air flow 4.2/5m3/min 8/10m3/min 18/20m3/min
Collection efficiency Min. 99.8% (by gravimetric method)
Rated voltage 3-phase, 200VAC 50/60Hz
Rated motor output 0.3kW(2P) 0.4kW(2P) 1.12kW(2P)
Rated current consumption ※1 1.6/1.6A or less 2.0/2.0A or less 4.7/4.5A or less
Working temperature 0 to +40℃
Working humidity Max. 85%RH, free from condensation
Noise (at 1m) 57dB(A) 63dB(A) 66dB(A)
Max. suction air temperature +50℃
Environmental standard RoHS2
Suction port diameter Ø100mm Ø125mm Ø150mm
Weight 25.0kg 30.0kg 50.0kg
Drain port Ø19 pipe

Mechanism

メカニズム

  1. Larger particles in the incoming air are filtered by inertial collision as a primary step.
  2. Smaller particles escaped from the primary filter are trapped by the secondary filter and then by the tertiary filter.
  3. Clean air goes out through the exhaust port.


Product lineup

OMC-F105A

OMC-F105A

Max. air flow

4.2/5m3/min

A complete set of supply

Oil Mist Collector : 1 unit Ø 100 Duct flange : 1 pc.  Duct hose band : 2 pcs.
Drain hose : 2m long Drain hose band : 1 pc. Anti-vibration rubber : 4 pcs. Instruction manual : 1 copy

Collection efficiency

Test oil : Water-insoluble cutting oil
Measuring instrument : Low volume air sampler type AN-200

捕集率

Dimensional drawing

外形寸法図

Mounting hole processing

取付穴加工図

Mounting cutout for duct flange

ダクトフランジ取付穴加工図


OMC-F110A

OMC-F110A

Max. air flow

8/10m3/min

A complete set of supply

Oil Mist Collector : 1 unit Ø 125 Duct flange : 1 pc.  Duct hose band : 2 pcs.
Drain hose : 2m long Drain hose band : 1 pc. Anti-vibration rubber : 4 pcs. Instruction manual : 1 copy

Collection efficiency

Test oil : Water-insoluble cutting oil
Measuring instrument : Low volume air sampler type AN-200

捕集率

Dimensional drawing

外形寸法図

Mounting hole processing

取付穴加工図

Mounting cutout for duct flange

ダクトフランジ取付穴加工図


OMC-F120A

OMC-F120A

Max. air flow

18/20m3/min

A complete set of supply

Oil Mist Collector : 1 unit Drain hose : 2m long Drain hose band : 1 pc. Instruction manual : 1 copy

Collection efficiency

Test oil : Water-insoluble cutting oil
Measuring instrument : Low volume air sampler type AN-200

捕集率

Dimensional drawing

外形寸法図

Mounting hole processing

取付穴加工図

Mounting cutout for duct flange

ダクトフランジ取付穴加工図


Option

Optional parts for OMC-F

オプション品

Filter, Duct hose, etc.

Cautions

・This product is intended for collecting general watersoluble and oil mist that generates during production process using various machine tools. Never have it inhale the following substances.

 - Flammable substances such as gasoline, thinner, benzin, kerosene and others as well as oil and cleaning liquid with an ignition point 70 degrees C or below,
 - Explosive substances such as aluminium, magnesium and titan as well as materials ridden with those substances,
 - Flammable liquid, mist and materials ridden with these substances,
 - Corrosive and adhesive substances and hazardous gas or air with a lot of unusual substances
 - Dust
 - Hot air exceeding 50 deg. C.
 - Large amount of liquid,
 - Substances that remarkably accelerate rusting of metals or aging of plastics

・This product should not be used in an atmosphere which contains chlorine, sulfuric or fluorine gasses, oxalic acid, xylene, or methyl tetrachloride and the like.
・Do not use this product in a corrosive atmosphere.
・Tampering or repairing the product should be strictly avoided. Please contact us for repairing service.
・Do not operate the product with its terminal box uncovered.
・Never touch the motor while the unit is in operation. Do not put your fingers or foreign matters into the rotating part of fan.
・Indoor use only. The altitude of the site of use should be lower than 2000 m.
・The site of use should be free from vibration or impact.
・Make sure that the packaging is not damaged on delivery.
・Use this product within the temperature range from 0℃ to +40℃ and humidity not exceeding 85%RH (no condensation).
・Impact, vibration or excess load should be avoided during transportation.
・Precision apparatuses should not be arranged near the exhaust port where fine particles may fall on.