Wiring accessories


OA-W Splittable type


For clamping and waterproofing a cable with connector

キャプコン OA-Wシリーズ セパレートタイプ

Features

Protection category Color Oilproof Weatherproof
IP67*only when fixed nipple with lock nut Black

Certificates/Approvals

EU RoHS2 China RoHS CE UL CSA PSE
・Applications For clamping and waterproofing D-sub, cannon plug, USB or other connector cables



Model/Specifications

Oilproof type Rubber bushing : Black

Model Applicable cable
diameter (mm)
Entry hole diameter(mm) Threads Mounting plate thickness Weight* Q'ty per package
OA-WH16-06/10 Ø6 - 10 Ø21 CTG16 4 mm or less 23g 10 pcs.
OA-WH22-06/13 Ø6 - 13① Ø28 CTG22 6 mm or less 42g 5 pcs.
OA-WH36-06/13 Ø42 CTG36 7.5 mm or less 68g

Weatherproof type Rubber bushing : Blue

Model Applicable cable diameter (mm) Entry hole diameter(mm) Threads Mounting plate thickness Weight* Q'ty per package
OA-WH16-06/10E Ø6 - 10 Ø21 CTG16 4 mm or less 23g 10 pcs.
OA-WH22-06/13E Ø6 - 13① Ø28 CTG22 6 mm or less 42g 5 pcs.
OA-WH36-06/13E Ø42 CTG36 7.5 mm or less 68g
Common : Working temperature -25 to +80℃  *Weight values are for Black color models.
*Rubber bushing color of Weatherproof OA-W36 models is black.
  • Note : The applicable cable size marked with ① changes by combination of the rubber bushings.

Applicable cable diameter(mm)
Rubber bushing A+B Ø6 - 10
Rubber bushing A only Ø10 - 13

Dimensional drawing

外形寸法図

Materials

材質

Cabtyre cable outer diameters

Instructions

コネクタを取付穴に通す。

1. Put the connector through the hole.

ニップルA・Bをはめ合わせる。

2. Fit the nipple parts
A and B together.

カチッと音がするまではめ込む。

3. Fit them closely until it clicks.

ロックナットを電線に通しニップルを固定する。

4. Pass cable through the locknut and secure the nipple.

締付キャップA・Bを電線に沿って組み合わせる。

5. Fit the Dome nut parts A and B together along the cable.

締付キャップを締めて電線を固定する。

6. Tighten the combined Dome nut to secure the cable.

【Caution】
※There may be no click sound due to the resin absorbing water, but this is only a temporary fit and does not affect product performance.
※When installing the lock nut, be careful not to install it at an angle.

When disassembling Nipple

For disassembling the Nipple, insert a screw driver into the groove of hexagon part and twist it off.

ニップルを分解する場合

  • Use only one cable for one hole.
  • Tightening torque and tensile strength differ depending on the material of cable coating and its hardness.
  • Tensile strength and waterproof performance drops when outer cable diameter changes due to aging.
  • Product performance are not guaranteed for cables other than the applicable size or round cables.
  • For proper torque management of the locknut and the dome nut , fix the nipple with a wrench and tighten the Dome nut.

Option

Model Applicable cable diameter(mm) Applicable models Weight Q'ty per
package
GH16-04/06B Ø4 - 6 OA-WH16-06/10 1g 10 pcs.
GH16-04/06BE OA-WH16-06/10E

Cautions

*Do not step foot or put load on the product. Do not paint the product.
*Do not use this product in oil or water.
*To prevent deterioration, avoid using or storing this product under the following atmospheres.
  1. Outside the range of working humidity and temperature
  2. Water vapor contained or high temperature/humidity air
  3. Acidic, alkaline or organic solvent-containing air (See Technical Data "Chemical resistance")
For any other special environmental conditions, please contact us before use.
  • For Oilproof Type (Rubber color : black)
    Do not expose to direct and continuous sunlight.
    Suitable for oily environments.
    *For non-oily places, use Weatherproof type.
  • For Weatherproof Type (Rubber color : blue)
    Avoid using in oily environments.
    For non-oily indoor places, Weatherproof type is recommended.