Go to global navigation

Read the article

Go to local navigation

Go to footer



Wiring accessories

Home > Wiring accessories > Insulation cap "QUICK CAP" lineup > Option OA-QTM Protection Cap

Option OA-QTM Protection Cap


Prevents dust accumulation between a cabtyre cable and wires

OA-QTM用保護キャップ

Certificates/Approvals

EU RoHS2 China RoHS CE UL CSA PSE

Model Specifications

Model Max. applicable cable diameter Applicable product Color Weight Q'ty per package
1st tier 2nd tier
QTM-34C Ø8×2 pcs. Ø11×2 pcs. OA-QTM34 Black 11g 20 pcs.
QTM-44C Ø8×2 pcs. Ø12×2 pcs. OA-QTM44 14g
QTM-64C Ø8×4 pcs. Ø11×4 pcs. OA-QTM64 15g 10 pcs.
QTM-633C Ø8×4 pcs. Ø10.5×4 pcs. OA-QTM633 14g
QTM-834C Ø8×4 pcs. Ø11.5×4 pcs. OA-QTM834 18g
QTM-844C Ø11×4 pcs. Ø14×4 pcs. OA-QTM844 26g 5 pcs.
Working temperature : -20 to +60℃
・Only occasionally the inner side of Protection Cap have some cavities due to air bubbles formed in DIP molding process. However, this will have no impact on functions.
・Any of Protection Caps is not applicable to other products than specified above.

Dimensional drawing

外形寸法図

Materials

 Vinyl chloride

カット図

The soft material tightly fits to the upper part of OA-QTM.
Cut the downside of the cap to fit the outer diameter of your cabtyre cable.

Instructions

電線を接続する。

1. Make wire connection to OA-QTM.

ケースへ入れる。

2. Fit in the housing of OA-QTM.

「パチン」と音がするまで押し込む。

3. Push down the housing until it makes a clicking sound.

キャップをはめ込む。

4. Fit Protection Cap on.

結束バンドなどで固定する。

5. Tie up the end.

Cautions

・Use and storage under the following conditions should be avoided. Failure to it can lead to deterioration of product quality.
  1. Outside the range of working humidity and temperature
  2. Water vapor contained or high temperature/humidity air
  3. Acidic, alkaline or organic solvent-containing air (See Technical Data "Chemical resistance")
For any other special environmental conditions, please contact us before use.